IEC 60268 7 PDF

IEC SOUND SYSTEM EQUIPMENT –- PART 7: HEADPHONES AND EARPHONES. Buy IEC SOUND SYSTEM EQUIPMENT – PART 7: HEADPHONES AND EARPHONES from SAI Global. IEC Ed. Sound system equipment – Part 7: Headphones and earphones IEC (E), is applicable to headphones, headsets, earphones.

Author: Dajar Mar
Country: South Sudan
Language: English (Spanish)
Genre: Health and Food
Published (Last): 4 June 2011
Pages: 118
PDF File Size: 13.41 Mb
ePub File Size: 1.79 Mb
ISBN: 510-2-99035-492-6
Downloads: 86340
Price: Free* [*Free Regsitration Required]
Uploader: Faenos

This approach provides the user with the flexibility to measure all or some of the characteristics of their headphone.

Test Setup for measuring headphone voltage sensitivity. In order to add these Signal Paths to your System Calibration or relink to existing Signal Paths, you should 77 each of the sequences individually and, if prompted, add or relink Paths to your System Calibration. Five separate sequences are provided, each designed to measure specific characteristics. Sound System Equipment — Part 7: It then calculates the voltage required to produce 1 mW into the rated impedance.

Software Requirements SoundCheck The Hz recorded time waveforms are processed using heterodyne analysis to derive their fundamental values.

Take the smart route to manage medical device compliance. A series of post processing steps calculates the attenuation curves, their average values and shows them on the final display. Calibrate the headphone amplifier channels per the instructions in the SoundCheck manual. The folder contains dependent files required to run the sequences. The sequence first plays a stepped sine through both channels of the DUT and captures the sound radiation from the DUT using 2 reference mics.

The sequence prompts the operator to enter the rated voltage and rated impedance of the DUT. A pink noise stimulus is played from the noise speakers and recorded by the occluded ears. Once calibrated, position the microphones 0. You may find similar items within these categories by selecting from the choices below:.

  FLEXISIGN 8.1 MANUAL PDF

Your basket is empty. Connect the impedance boxes between the headphone amp out and 77 input.

IEC-60268-7 Headphone Test Sequences

The data from each loop iteration is displayed as it is acquired. Accept and continue Learn more about the cookies we use and how to change your settings. This website is best viewed with browser version of up to Microsoft Internet Ic 8 or Firefox 3. First, a pink noise stimulus is played from the noise speakers and recorded by the unoccluded ears.

BS EN – Sound system equipment. Headphones and earphones

It is recommended that the sequences be run directly from the IEC folder. A statistics step calculates the mean of the 3 unoccluded measurements.

Learn more about the cookies we use and how to change your settings. No – I don’t want to receive the latest audio test information by email. Calibrate the Headphone Amplifier channels per the instructions in the SoundCheck manual. Hardware Requirements In order to run the sequences, the following hardware is required: Please download Chrome or Firefox or view our browser tips. This sequence satisfies the requirements of Section 8. You are ready to start the sequence.

The user is first prompted to enter the rated voltage. The sequence uses a stepped sine stimulus to measure frequency response, THD and impedance, a composite signal of 70 Hz and Hz with an amplitude ratio of 4: We use cookies to make our website easier to use and to better understand your needs.

IEC Headphone Sequences – Listen, Inc.

This sequence uses a pink noise stimulus to characterize the passive, active and total attenuation of noise cancelling headphones. Headphone Voltage Sensitivity Final Display. Crosstalk and radiation curves are then shown on the final display. Relink dialog Here is a list of sequences and their default signal paths unique paths are in bold: The sequence then goes through a series of acquisition steps to generate four fundamental curves which are then post-processed to calculate crosstalk.

  IOMEGA ICONNECT USER MANUAL PDF

Matthew Miller November 15, – 6: The content you have requested is available only to registered visitors. Calibrate the microphones per the instructions in the SoundCheck manual.

It then enters a loop which will run 5 times. If more than 4 input channels are available, all input signal paths may be assigned to separate hardware channels.

BS EN 60268-7:2011

If passive, connect to the headphone amp or separate audio power amplifier You are ready to start the sequence. Search all products by. Marking, Microphones, Audio systems, Ratings, Designations, Instructions for use, Headphones, Classification systems, Frequency response, Earphones, Audio equipment, Voltage measurement, Impedance measurement, Testing conditions, Preamplifiers, Comparative tests, Acoustic measurement, Electrical wave measurement, Electrical properties and phenomena, Acoustic testing.

It can also be used to characterize the passive attenuation only of a standard non-ANC headphone. The spectra are then power summed to derive a single SPL value and the Hz fundamentals are post processed to derive their SPL values.

Find Similar Items This product falls into the following categories. You 60286 experience issues viewing this site in Internet Explorer 9, 10 or Registration required The content you have requested is available only to registered visitors.

There are several unique Signal Paths used in the sequences which are not a part of the default SoundCheck installation.

Headphones and earphones Isc Click to learn more. The play and record acquisition takes place 3 times and the user is prompted to reposition the DUT on the HATS in between acquisitions.